Get ready to see hazardous levels of oxygen, toxic and combustible gas, and volatile organic compounds (VOCs) as you never have before.

  • 1-6 Gas monitor
  • Full-colour LCD display
  • 24 Sensor options including PID and IR
  • iNet™ Ready and Docking Station™ compatible

Request More Information

Get ready to see hazardous levels of oxygen, toxic and combustible gas, and volatile organic compounds (VOCs) as you have never seen them before. The MX6 iBrid™ is more than an intelligent hybrid of Industrial Scientific’s best monitoring technologies. It’s the first gas monitor to feature a full-colour LCD display screen. 

The display improves safety,with clear readings in low light, bright light or anywhere in between. Whether the work is outside, inside or underground, it’s easy to see what gas hazards lurk in the immediate work environment. And a colour display is more than eye-catching. It allows the user to step through instrument settings and functions with an intuitive menu and the instrument’s five-way navigation button. It even supports the option of on-board graphing for easily interpreting direct readings and recorded data. 

And, the MX6 iBrid is our most rugged instrument ever. It carries a lifetime warranty and is fully compatible with our DS2 Docking Station™iNet DS and iNet™ Instrument Network

Specifications

Instrument Warranty:

Warranted for as long as the instrument is supported by
Industrial Scientific Corporation

Case Material:

Lexan/ABS/Stainless Steel w/protective rubber overmould

Dimensions:

135 mm x 77 mm x 43 mm (5.3" x 3.05" x 1.7") – without pump
167 mm x 77 mm x 56 mm (6.6” x 3.1” x 2.2”) – with pump

Weight:

409 g (14.4 oz) typical – without pump; 511 g (18.0 oz) typical – with pump

Display/Readout:

Colour Graphic Liquid Crystal Display

Power Source/Run Time:

Rechargeable Lithium-ion (Li-ion) Battery Pack (24 hours) – without pump

Rechargeable Extended-Range Lithium-ion Battery Pack

(36 hours) – without pump

Replaceable AA Alkaline Battery Pack (10.5 hours) – without pump

Operating Temperature Range:

-20ºC to 55ºC (-4ºF to 131ºF) typical

Operating Humidity Range:

15%-95% non-condensing (continuous)

Measuring Ranges:

SENSORS

Range

Resolution

Catalytic Bead

Combustible Gas

0-100% LEL

1%

Methane

0-5% vol

0.01%

Electrochemical

Ammonia

0-500 ppm

1

Carbon Monoxide

0-1,500 ppm

1

Carbon Monoxide (High Range)

0-9,999 ppm

1

Carbon Monoxide/Hydrogen low

0-1,500 ppm

1

Chlorine

0-50 ppm

0.1

Chlorine Dioxide

0-1 ppm

0.01

Carbon Monoxide/

Hydrogen Sulphide

CO: 0-1,500 ppm

H2S: 0-500 ppm

1

0.1

Hydrogen

0-2,000 ppm

1

Hydrogen Chloride

0-30 ppm

0.1

Hydrogen Cyanide

0-30 ppm

0.1

Hydrogen Sulphide

0-500 ppm

0.1

Nitric Oxide

0-1,000 ppm

1

Nitrogen Dioxide

0-150 ppm

0.1

Oxygen

0-30% vol

0.1%

Phosphine

0-5 ppm

0.01

Phosphine (High Range)

0-1,000 ppm

1

Sulphur Dioxide

0-150 ppm

0.1

Infrared

Hydrocarbons

0-100% LEL

1%

Methane (% vol)

0-100% vol

1%

Methane (% LEL)

0-100% LEL

1%

Carbon Dioxide

0-5% vol

0.01%

Photoionisation

VOC

0-2,000 ppm

0.1

Certifications:

UL

UL – Class I, Groups A,B,C,D T4; Class II, Groups F,G; AEx ia d IIC T4

CSA

Class I, Groups A,B,C,D T4; Ex ia d IIC T4;

MSHA

CFR30, Part 22, Intrinsically safe for methane/air mixtures

ATEX

Ex ia IIC T4 Ga / Ex ia I Ma; IP65 (IP64 pump version);
Equipment Group and Category: II 1G/I M1 (I M2 w/IR sensor)

IECEx

Ex ia IIC T4 Ga/Ex ia I (Ex ia d I w/IR sensor)

ANZEx

Ex ia s Zone 0 I, IP64 Asp., IP65 Dif. Ex ia s Zone 0 IIC T4

INMETRO

Ex ia d IIC T4 Gb

GOST-R

PBExiadI X / 1ExiadIICT4 X

KOSHA

Ex d ia IIC T4

China Ex

Ex ia d I/IIC T4

China CPC:

Metrology Approval

* These specifications are based on performance averages and may vary by instrument


BASE INSTRUMENTSENSORS
OPTIONS
BATTERY
OPTIONS
VERSION
OPTIONS
LANGUAGE OPTIONS

MX6 iBrid Logo

Supplied with Monitor:
universal charger, nylon carrying case, belt clip, calibration cup, wrist strap, maintenance tool, manual, quick start guide, calibration tubing, dust filter/water stop (aspirated), calibration fitting (aspirated), sample tubing (aspirated).
Combustible Gases:
LEL (Pentane) LEL (Methane)
CH4 IR (0-100% vol.) CH4 (0-5%)
Hydrocarbons IR (0-100% LEL)

Volatile Organic Compounds: PID

Toxic Gases:
H 2 S, O 2 , NO 2 , CO, CO/H 2 S,
NH3, Cl2, ClO2, PH3, CO High,
SO2, HCl, HCN, H2, PH3 High,
NO, CO/H2 low interference, CO2 IR
Li-ionDiffusionEnglish
Li-ion/Ext. RangePumpFrench
Alkaline Spanish
Li-ion MSHA/AUS German
Li-ion/Ext. Range MSHA/AUS Italian
Alkaline MSHA/AUS Dutch
Li-ion GOST Portuguese
Li-ion/Ext. Range GOST Indonesian
Alkaline GOST Russian
  Polish
  Czech

 

Build and price your MX6 online with the MX6 instrument builder.
www.indsci.com/MX6builder.aspx

 

MOST COMMON INSTRUMENT CONFIGURATIONS for (UL/CSA)
PART NO.DESCRIPTION
MX6-K1230101MX6 - LEL, CO, H2S, O2, Li-ion
MX6-K0230101MX6 - LEL, H2S, O2, Li-ion
MX6-K1030101MX6 - LEL, CO, O2, Li-ion
MX6-K0030101MX6 - LEL, O2, Li-ion
MX6-K123R211MX6 - LEL, CO, H2S, O2, PID, Ext. Li-ion, Pump
MX6-K1235101MX6 - LEL, CO, H2S, O2, SO2, Li-ion
MX6-K0235101MX6 - LEL, H2S, O2, SO2, Li-ion
MX6-0000R211MX6 - PID, Ext. Li-ion, Pump
COMMON INDUSTRY CONFIGURATIONS for (UL/CSA) 
Petroleum Refining:
MX6-KJ53R211MX6 - LEL, CO/H2S, O2, SO2, PID, Ext. Li-ion, Pump
Brewing/Bottling/Wineries:
MX6-K103Q211MX6 - LEL, CO, O2, CO2, Ext. Li-ion, Pump
Pulp/Paper:
MX6-KJ835101MX6 - LEL, CO/H2S, O2, SO2, ClO2, Li-ion
HazMat:
MX6-K673R211MX6 - LEL, O2, NH3, Cl2, PID, Ext. Li-ion, Pump
Mining:
MX6-M1030401MX6 - CH4 (%), CO, O2, Li-ion (MSHA/AUS)
Mining (Diesel Applications):
MX6-M1D34401MX6 - CH4 (%), CO, O2, NO2, NO, Li-ion Ext.

  1. MX6 Docking and Calibration Stations

     
    Part Number Description
    18109329-ABC 

    DSX™ Docking Station for MX6*

    1. – DSX Mode:
         0 = DSX Standalone
         1 = DSXi Cloud-connected
         2 = DSX-L Local Server
    2. – Number of Gas Inlet Ports:
         3 = 3 Ports
         6 = 6 Ports
    3. – Power Cord Type: 1 = North America, 2 = EU, 3 = AUS, 4 = UK
     
     

     

    *DSX Docking Station Kits Include: Choice of Standalone or Cloud-connected 3-port DSX docking station, 116L calibration gas (appropriate mix) with demand flow regulator with iGas® pressure switch, North American power cord, USB storage device (Standalone only).
  2. MX6 Remote Sampling and Confined Space Kit

     
    Part Number Description
    MX6 Confined Space Kits Click for Details MX6 Confined Space Kits
    SP6 Motorised Sampling Pump
    18106765
    SP6 Motorised Sampling Pump
    Calibration Tubing Assembly with Integrated 'T' Fitting
    17116096
    Calibration Tubing Assembly with Integrated "T" Fitting (For use when calibrating a monitor with pump using a positive flow regulator)

  3. MX6 iBrid® Carrying Cases 

    Part Number Description
    Hard Leather Carrying Case, Aspirated
    18106880-0
    Hard Leather Carrying Case, Aspirated 
    Hard Leather Carrying Case, Aspirated, Without Window
    18106880-1
    Hard Leather Carrying Case, Aspirated, Without Window
  4. MX6 iBrid® Chargers and Batteries

    Part Number Description
    Battery Charger, 12V
    18107011
    Battery Charger, 12V
    MX6 Battery Charger, 5-Unit
    18107136
    Battery Charger, 5-Unit
    18107250 MX6 Truck Mount Charger, Hard-wired
    18107243 MX6 Truck Mount Charger, 12V
    Rechargeable Li-ion Battery Pack, UL/CSA/ATEX
    17131038-2
    Rechargeable Li-ion Ext. Battery Pack, UL/CSA/ATEX
    Rechargeable Li-ion Battery Pack, MSHA/AUS
    17131038-5
    Rechargeable Li-ion Ext. Battery Pack, MSHA/AUS
    Alkaline Battery Pack, UL/CSA/ATEX
    17131046-3
    Alkaline Battery Pack, UL/CSA/ATEX
    Alkaline Battery Pack, MSHA/AUS
    17131046-6
    Alkaline Battery Pack, MSHA/AUS

    18107086
    MX6 iBrid™ Datalink – Software included

    18107094
    MX6 iBrid™ Battery Charger/Datalink, universal – Software included
  5. MX6 iBrid® Sensors

    Part Number Description
    17124975-1 Carbon Monoxide (CO)
    17124975-2 Hydrogen Sulphide (H2S)
    17124975-3 Oxygen (O2)
    17124975-4 Nitrogen Dioxide (NO2)
    17124975-5 Sulphur Dioxide (SO2)
    17124975-6 Ammonia (NH3)
    17124975-7 Chlorine (CI2)
    17124975-8 Chlorine Dioxide (CIO2)
    17124975-9 Phosphine (PH3)
    17124975-A Hydrogen Chloride (HCI)
    17124975-B Hydrogen Cyanide (HCN)
    17124975-C Hydrogen (H2)
    17124975-D Nitric Oxide (NO)
    17124975-E  Phosphine (PH3) (high) 
    17124975-G Carbon Monoxide (H2 low)
    17124975-H Carbon Monoxide (high)
    17124975-J Carbon Monoxide/Hydrogen Sulphide (CO/H2S)
    17124975-K %LEL (Pentane)
    17124975-L %LEL (Methane)
    17124975-M Methane (0-5% volume)
    17124975-N Methane IR (0-100% volume)
    17124975-P Hydrocarbons IR (0-100% LEL)
    17124975-Q Carbon Dioxide IR (0-5% volume)
    17124975-R PID (VOCs)
    17124975-S Methane (0-100% LEL)

Powered By OneLink